The board was still cloudy from the last session, with flux dried wherever it had run out from the joints. I wanted to see what I had actually done before I went any smaller, so I started by cleaning it.
Cleaning off the flux
I used 99% isopropyl alcohol and a soft-bristle electronics brush, and worked over the residue around the 0603 column I had already soldered, including the pads for R34 through R38 and the nearby lamp-side footprints. The cloudy film came up more easily than I expected, and the soldermask underneath was suddenly readable again.
The joints underneath
With the flux gone, it was harder to talk myself into thinking the 0603 capacitors at C13 through C18 were fine. Several of the parts sit tilted on the pads, and the solder on the right-hand ends rises into peaks instead of wetting the termination and lying down. The parts are only getting smaller, so it felt like time to re-evaluate how I was putting the solder down.
Copper wick
I have copper desoldering braid in the kit, and this was the point at which I started getting more comfortable using it. The idea was not to make the joints look finished, and not to chase a perfect fillet just yet. I wanted the horns gone, and the aim for now is still just to pass a continuity check, not to make the work look pretty.
The method that worked for me was straightforward. I used a fresh end of braid, put a little flux on it, laid that end flat on the joint, and rested the iron on top of the braid rather than trying to poke at the solder directly. Once the solder melted and wicked up into the copper, I lifted the braid and the iron together so I would not dump a blob back onto the pad, and then clipped off the used section.
A grain of sand
I moved on to the last resistor column, the 0402s, which are absolutely ridiculously tiny. Before I started, I wanted a photograph for scale, and I grabbed the wrong parts. At this size the packages look almost alike, and the first fingertip shot was of the 0603 resistors I had already been using. The real 0402s are smaller still, and truly grain-of-sand like: about 1.0 by 0.5 millimeters.
I fluxed the 0402 pads along the T6 column and tinned each one with the least amount of solder I could manage, just a small bump on one pad of each footprint, with no parts on the board yet. Then I held each resistor in place, tacked the tinned side, and soldered the other end the same way, a tiny bit of solder at a time.
The first one went on, not perfectly, but it was on. After that I leaned heavily on the microscope to sit the next parts, and I’m getting more used to working under it instead of trying to place them by naked eye. The second and third sat a little straighter than the first.
I got eight of them on the board. The rest disappeared, and I think I swept them off with my arm when I leaned down on the mat. I could not find them again, which, at the size of a grain of sand, is easy to believe.
I did get a reading across the ones I had placed, 132.5 to 132.6, and that was enough. I am satisfied and humbled by the exercise.
Leaning over parts that small for that long left my neck and back tight, so I went for a walk to work the tension out. It felt like the right way to close the session.
What’s next
The lamp circuit is still ahead, and I’ll photograph the joints as I go, including the ones I would rather retake.